Frequently Asked Questions (FAQ) for Test Accessories
1) Are your DC blocks Inner or Outer or Inner/Outer?
All of the models listed in the catalog are Inner only. For Outer or Inner/Outer, please contact JFW at sales@jfwindustries.com.
2) What is the difference between an Impedance Matching Pad and an Impedance Matching Transformer?
Impedance matching pads use a resistive design to achieve the impedance change. Impedance matching transformers use a reactive design (often with a wire-wound toroid) to achieve the impedance change.
3) What are the pros and cons of impedance matching transformer versus impedance matching pads?
Matching Transformer Pros
- Low insertion loss
Matching Transformer Cons
- Narrow frequency band
- Low power
Matching Pad Pros
- Wide frequency band (and works at DC)
- High power capabilities
Matching Pad Cons
- High insertion loss
4) What are feedthru terminations?
A 50 Ohm feedthru termination is used to connect 50 Ohm RF cable to the high impedance inputs of test instruments (oscilloscope) and maintain proper impedance loading of the RF cable.