Model 50T-001-BNC-M termination 50 Ohm 1 Watt BNC male

50 Ohm Termination rated for 1 Watt with BNC male connectorTerminations & Mismatch Loads
(0.5 to 2 Watts)

JFW’s online 50 Ohm Low power termination and mismatch load models are listed in the table below.  JFW has been designing, manufacturing, and delivering quality terminations and mismatch loads for over 30 years.  Our mismatch loads allow you to select the impedance mismatch your RF testing requires.

Termination

The terminations listed in the model table are all 50 Ohm impedance.  Terminations are used to properly terminate a port in the matching impedance to prevent RF signal reflections.

Mismatch Load

The mismatch loads in the model table have model numbers that end with -XXX.  The -XXX is used to specify the mismatch value.  For example, JFW model #50T-464-2.0 SMA M is a  2.0:1 mismatch load (i.e. 100 Ohms) with a 50 Ohm SMA male connector.

For your specific application, please contact JFW or use our Inquiry Form.

JFW Model #ImpedanceRF ConnectorFrequency RangeRF Input PowerDescription
50T-00150 OhmBNC maleDC-2.2 GHz1 WattTermination
50T-00250 OhmBNC femaleDC-2.2 GHz1 WattTermination
50T-00750 OhmN maleDC-8 GHz2 WattTermination
50T-14250 OhmN Male (optional Bead Chain)DC-8 GHz2 WattTermination
50T-14350 OhmTNC male w/ Bead ChainDC-8 GHz2 WattTermination
50T-26150 Ohm7/16DC-2 GHz2 WattTermination
50T-30050 OhmRP-TNCDC-3 GHz2 WattTermination
50T-36350 Ohm7/16DC-4 GHz2 WattTermination
50T-37650 Ohm4.1/9.5, BNC, N, SMA, TNCDC-4 GHz2 WattTermination
50T-70050 OhmSMA maleDC-18 GHz1 WattTermination
50T-464-XXX50 OhmBNC, N, SMA, TNCDC-3 GHz2 WattTermination or Mismatch Load
50T-588-XXX50 OhmBNC, N, SMA, TNCDC-1 GHz2 WattTermination or Mismatch Load
50T-60550 Ohm4.3/10DC-6 GHz2 WattTermination
50T-60650 OhmIP67 rated N, SMA, TNCDC-6 GHz2 WattTermination
50T-60850 OhmN, SMA, TNCDC-6 GHz2 WattTermination
50T-70150 OhmNDC-18 GHz2 WattTermination
50T-70250 Ohm2.92mmDC-40 GHz2 WattTermination
50T-72450 OhmSMADC-8.4 GHz2 WattTermination
50T-72750 OhmNDC-8.4 GHz2 WattTermination
50T-71850 OhmSMADC-18 GHz2 WattTermination
50T-72550 OhmSMADC-26.5 GHz2 WattTermination
50T-70650 OhmTNCDC-18 GHz2 WattTermination
50T-74550 Ohm2.4mmDC-50 GHz2 WattTermination
50T-73950 OhmTNCDC-8.4 GHz2 WattTermination

If you have specific mechanical restrictions, RF specifications, or required unit screening, please contact us. JFW does not charge NRE’s for new termination models. We pride ourselves in the ability to offer custom models with pricing in-line with our catalog models.